In large projects, components can be more than 10km away from the IFC global origin, or components can be 10km apart from each other. In these cases, however, the models are automatically placed closer to each other based on the first loaded model.
If this is not the desired behavior, the automatic move can be disabled in the settings file:
If the project folder is used: Disable the Project folder in the project by unchecking all folders in the project folder settings, and save the settings
Close BIMcollab Zoom
Go to C:\Users\\AppData\Roaming\Kubus\BIMcollab Zoom
Open settings.xml
Find the line "force_move_faraway_models", and change 1 to 0
Save the settings file
Open BIMcollab Zoom
Load the models again
If the project folder is used: Connect to the project and set up the Project folder again